• Users Online: 64
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2022  |  Volume : 3  |  Issue : 1  |  Page : 25-31

Outcomes of supraflex sirolimus eluting coronary stents


1 Department of Cardiology, Apusnova Multisuperspeciality Hospital, Meerut, Uttar Pradesh, India
2 Department of Cardiology, Super Speciality Hospital GMC, Srinagar, Jammu and Kasmir, India
3 Batra Hospital and Medical Research Centre, New Delhi, India

Correspondence Address:
Dr. Sheikh Mohammad Tahir
Super Speciality Hospital GMC, Srinagar, Jammu and Kasmir
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jascp.jascp_25_21

Rights and Permissions

Background: The introduction of Sirolimus Eluting Coronary Stents (SES) was a major breakthrough in interventional cardiology. The large, randomized, clinical trials using SES have shown a remarkable reduction in angiographic restenosis and target vessel revascularization (TVR) compared with bare-metal stents as well as other drug-eluting stents (DESs). However, there is only limited data on the outcome of Indian patients treated by DES of Indian origin. The purpose of the study was to evaluate the outcomes of the supraflex sirolimus-eluting coronary stents for the treatment of coronary artery disease and to determine major adverse cardiovascular and cerebrovascular events (MACCE). Materials and Methods: This was a single-centre, observational, nonrandomized study that enrolled unselected real-world patients at a tertiary care center who had undergone implantation with supraflex sirolimus-eluting stents. The primary end-point of the study was MACCE, which is a conglomeration of cardiac death, target lesion revascularization (TLR), TVR, cerebrovascular accident (CVA), and heart failure at 1-year follow-up. Results: A total of 100 patients were intervened successfully with sirolimus-eluting stents. Out of total patients, diabetes and hypertension were observed in 38% and 35% of patients. According to ACC/AHA classification, there were 68% Type B lesions and 32% Type C lesions. At 1-year follow-up, MACE was found to be 11%, which is a composite of 4% TLR, 3% TVR, 1% CVA, and 5% heart failure. Diabetes (P = 0.02), hypertension (P = 0.01), kidney dysfunction (P = 0.002), and LV function (P = 0.01) strongly correlate with outcome (MACCE). Conclusion: There was an acceptable rate of adverse events after implantation of the supraflex sirolimus-eluting stents, although it was slightly higher compared to other studies. Diabetes, hypertension, kidney dysfunction, and LV function strongly correlate with outcome (MACCE).


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed49    
    Printed2    
    Emailed0    
    PDF Downloaded5    
    Comments [Add]    